Reservoir & Conduit
Gross head H220.0 m
5300600 m
Penstock diameter D3.20 m
0.54.258.0 m
Penstock length L640 m
5015253000 m
Wall roughness ε0.600 mm
drawnwelded steelcorroded
Minor loss coeff. ΣK1.10
0intake+bends5.0
ΣK covers intake, trashrack, bends, inlet valve and draft-tube exit. Applied to the penstock velocity head v²/2g.
Working Fluid
Water density ρ998.2 kg/m³
950fresh 9981200 silt
Dynamic viscosity μ1.002 mPa·s
80 °C20 °C0 °C
Kinematic viscosity ν = μ/ρ feeds the Reynolds number and therefore the friction factor.
Flow Control
Discharge setpoint Q45.0 m³/s
0125250 m³/s
Discharge is set by wicket-gate position. The delivered flow follows the setpoint through the rigid water-column time constant Tw = LQ / (gA·Hn).
Machine
Turbine efficiency ηt90.0 %
406896 %
Generator efficiency ηg97.2 %
859299 %
Grid frequency
Synchronous speed n = 120f / p. Pole count is selected as the fastest standard machine keeping specific speed within the Francis range.
View
Keys: space pause · g grade lines · p profile · r reset.
DISCHARGE Q — m³/s
0
TOTAL HEAD LOSS — m
0
ELECTRICAL POWER — MW
0
CUMULATIVE ENERGY — MWh
0